Metal-Fab
TGGA30 (Galvanized Casing)
Note: Twist Look Pipe overlaps 1-1/2" when joined together. Therfore, assembled length is 1-1/2" less than listed length.
30° angles are used in pairs to obtain lateral movement where more angle is required.
Double-Wall Factory-Built Chimney Systems for use with listed wood, coal, oil, gas or propane-fired appliances in accordance with the Standards for Chimneys, Fireplaces, Vents and Solid-Fuel Burning Appliances, NFPA 211, BOCA National Mechanical Code, Standard Mechanical Code and the Uniform Mechanical Code.
Temp/Guard® All-fuel products, diameters 6"- 8" are tested and listed to UL 103HT for continuous operating temperatures up to 1000°F and 2100°F intermittent. Temp/Guard features a twist-lock connection that eliminates the need for sheet metal screws and aids in proper joint alignment. Temp/Guard utilizes a ceramic fiber blanket insulation that reduces “hot spots” and prevents insulation settling during transportation and installation, increasing product safety and reliability. Our factory-built chimneys have the smallest clearance to combustibles of 1.5" in the industry, reducing the chimney system footprint that saves on cost and time.
Evaporative Cooler In-Line Scale Eliminator Cartridge
Evaporative Cooler Sealer, 13-oz. Aerosol
Imperial 12" x 6" White Sidewall Grille
Imperial Manufacturing 4" x 8" Brown Floor Register
Lambro 4 inch x 8 foot UL 2158A Clothes Dryer Transition Foil Flex Duct